Menu

Digital Mass Notification Announcer

Model: DNA-510A

  • Five programmable trigger inputs to activate a message and/or alert tone
  • Over 5 minutes of total message record time
  • Record up to 5 different emergency messages
  • Ten different pre-recorded alert tones:
    1. Code 3 Temporal (ANSI S3.41) Slow Whoop
    2. Attack Wail*
    3. Security Breach*
    4. Fast Whoop
    5. Hi/Low Siren
    6. Alert Siren*
    7. Weather Alert
    8. Buzzer
    9. All Clear
    10. Brahms’ Lullaby
  • *Note: Looping recordings of actual emergency sirens.
  • Call progress detection for automatic hang up on CPC, busy signal, dial tone or 20 seconds of silence (during live page only)
  • Separate volume controls for paging, messages, and alert tones
  • Automatically interrupts current page or background music to inject emergency announcement, alert tones or live page
  • Non-volatile memory – retains programming during power outage
  • NO & NC trigger output contacts for activating flashing beacon (BLK-4-EWP), Alarm Dialer (K-202-DVA), etc.
  • Access code to prevent fraudulent use
  • Connects directly to an unused line input (trunk), station port of a phone system, a dedicated phone line or to a SIP VoIP phone system using an ATA
View all features
Add to Pick List Added to Pick List

Questions?

We are here to help!

Product Details

The DNA-510A is a digital mass notification announcer, capable of providing up to 5.25 minutes of digitally recorded voice emergency instructions and alert tones over your existing paging system from either touch tone commands or five separate trigger inputs.

The DNA-510A connects to a phone line, analog phone system station, a phone system’s unused trunk/line input, or to a SIP VoIP phone system using an ATA, allowing you to securely page, trigger emergency messages and/or alert tones and program the unit from any remote touch tone phone.

When activated, the DNA-510A will interrupt any current paging or background music and inject an emergency voice message and/or alert tone over your paging system. A live page can also be announced.

The DNA-510A can be programmed to repeat one up to 5.25 minute message, two up to 2.6 minute messages, three up to 1.7 minute messages, four up to 1.3 minute messages or five up to 1 minute messages. It can also be programmed with up to 9 different pre-recorded alert tones for emergency mass notification of: evacuation, lock down, severe weather, fire, bomb threat, hazardous material release, tornado, flash flood, terrorist alert, all-clear, etc.

Applications

Provide Emergency Mass Notification for:
•  Schools
•  Factories
•  Restaurants
•  Churches
•  Theaters
•  College campuses
•  Auditoriums
•  Dormitories
•  Office buildings
•  Hospitals

Baby Announcer for Hospitals/Clinics (click here for more info)

Features

  • Five programmable trigger inputs to activate a message and/or alert tone
  • Over 5 minutes of total message record time
  • Record up to 5 different emergency messages
  • Ten different pre-recorded alert tones:
    1. Code 3 Temporal (ANSI S3.41) Slow Whoop
    2. Attack Wail*
    3. Security Breach*
    4. Fast Whoop
    5. Hi/Low Siren
    6. Alert Siren*
    7. Weather Alert
    8. Buzzer
    9. All Clear
    10. Brahms’ Lullaby
  • *Note: Looping recordings of actual emergency sirens.
  • Call progress detection for automatic hang up on CPC, busy signal, dial tone or 20 seconds of silence (during live page only)
  • Separate volume controls for paging, messages, and alert tones
  • Automatically interrupts current page or background music to inject emergency announcement, alert tones or live page
  • Non-volatile memory – retains programming during power outage
  • NO & NC trigger output contacts for activating flashing beacon (BLK-4-EWP), Alarm Dialer (K-202-DVA), etc.
  • Access code to prevent fraudulent use
  • Connects directly to an unused line input (trunk), station port of a phone system, a dedicated phone line or to a SIP VoIP phone system using an ATA

Certifications

  • FCC Part 68
  • FCC Part 15
  • ANSI

Specifications

  • Power: 120V AC/12V DC 500mA UL listed adapter provided
  • Dimensions: 5.25” x 3.58” x 1.75” (133 mm x 91 mm x 44 mm)
  • Weight: 1.3 lbs (0.6 kg)
  • Environmental: 32°F to 90°F (0°C to 32°C­­­­­­) with 5% to 95% non-condensing humidity
  • Sampling Rate: 80 Kbs
  • Audio Output: 600 Ohm with volume adjustable potentiometer, maximum level = +8 dBm/ 2V RMS across 600 Ohm load
  • Page Trigger Output: 12V DC (20mA maximum) or NO/NC relay contacts (1A 30V DC / 0.3A 110V AC maximum)
  • Connections: 19 position cage clamp terminal strips


Questions?

We are here for you!

Contact Us
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.