Menu

Twelve Line Ring Shaper / Booster

Model: RG-212

  • True Sine wave ring signal output
  • Boosts ring to 4 REN
  • Caller ID compatible
  • Easy RJ-21X installation
  • Compatible with distinctive ringing services
  • Will not affect normal line operation
  • Reshapes troublesome square wave ringing
  • Fax and modem compatible
  • Not compatible with pulse dialing
Add to Pick List Added to Pick List
Software & Downloads

Product Manual

Questions?

We are here to help!

Product Details

The RG-212 ring generator is designed to reshape and increase the ringing power of up to 12 analog PABX extensions, FXS ports, IP phone system analog ports, or any other telecom devices which provides ringing.

The RG-212 duplicates the incoming ring cadence allowing it to be compatible with custom ringing features. Each line is capable of ringing four 1 REN or eight 0.5 REN telephones and does not affect normal operation of the telephone line or features, such as caller ID, call waiting, hookswitch flash features, CPC signaling, etc.

For other multi-line applications, use Viking models RG-204 (4 line) or RG-224 (24 line). For single line applications, use the Viking model RG-4. The Viking model RG-10A may be used for single line higher drive output applications up to 12 REN.

Applications

  • Boost ringing on FXS ports or IP phone system analog ports that are weak or fail
  • Boost ring power on analog PABX/KSU stations that are weak or fail
  • Reshapes troublesome distorted ringing signals

Features

  • True Sine wave ring signal output
  • Boosts ring to 4 REN
  • Caller ID compatible
  • Easy RJ-21X installation
  • Compatible with distinctive ringing services
  • Will not affect normal line operation
  • Reshapes troublesome square wave ringing
  • Fax and modem compatible
  • Not compatible with pulse dialing

Specifications

  • Power: 120V AC / 15V AC 2.2A UL listed adapter provided
  • Dimensions: 483mm x 241mm x 44mm (19” x 9.5” x 1.75”)
  • Shipping Weight: 3.2kg (7 lbs)
  • Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95% non-condensing humidity
  • Incoming Ring Detection: 20-150 VAC
  • Ring Generator: 90 VAC nominal, 55 VAC @ 4 REN load
  • Ringwave Shape: Sine wave
  • Connections: (2) RJ-21X female connectors


Questions?

We are here for you!

Contact Us