Menu

Emergency Phone with Enhanced Weather Protection for Viking Outdoor Enclosures

Model: E-1600-912-IP-EWP

  • Fits seamlessly within Viking VE-9×12 Outdoor Enclosures
  • Automatic polling and programming software included
  • 2 Amp relay contacts for door/gate or SL-2 strobe light control
  • SIP compliant
  • Outbound Proxy, Authentication ID, Peer to Peer, VLAN Tagging
  • PoE powered (class 1, <4 Watts)
  • Automatic Noise Canceling (ANC) for clear audio, even in noisy environments
  • Meets ADA requirements for Emergency Phones:
    • Automatically lights the “Call Connected” LED
    • Transmits a unique location I.D. code or voice announcement
    • Grade 2 Braille label for the visually impaired
  • Non-volatile digital voice announcer with 28 seconds of voice memory
  • Handsfree operation
  • Dials up to 5 emergency numbers
  • Cycles through backup phone numbers on busy or no-answer
  • Hangs up on busy signal, time-out or touch tone command
  • Extended temperature range of -40°F to 140°F
  • VoIP eliminates the need for “Push to Talk” mode
  • Network downloadable firmware
  • Diagnostics for testing microphone, speaker, and relay
  • Includes Enhanced Weather Protection (EWP), EWP products are designed to meet IP66 Ingress Protection Rating
  • Optional VE-SPG Hinge Spring
  • Optional PB-100 Polling System
  • Optional BLK-4-EWP Strobe Light Kit
  • Optional LC-6 Six Port Concentrator
  • Optional red “Emergency” label (part 261529) for VE-9×12 Enclosure
View all features
Add to Pick List Added to Pick List

Questions?

We are here to help!

Product Details

The E-1600-912-IP-EWP ADA Compliant Emergency Phone is designed to fit in Viking VE-9×12 Outdoor Enclosures. This emergency phone is designed to provide quick and reliable handsfree communication for SIP VoIP phone systems with PoE. The phone meets ADA requirements for elevator/emergency telephones, and can be programmed from any touch tone phone or PC on the same LAN or remotely using a static IP address. The phone can dial up to 5 programmable emergency numbers.

The E-1600-912-IP-EWP VoIP emergency phone can be programmed to automatically deliver a digital announcement to identify the location of the emergency call. Alternatively, a DTMF touch tone code may also be delivered. The stainless steel button features an built-in red LED that can be initiated manually or automatically to show “Call Connected”. All programming parameters, including phone numbers and location numbers, are stored in non-volatile memory, requiring no batteries. The unit is PoE powered (class 1, <4 Watts).

The E-1600-912-IP-EWP is equipped with Enhanced Weather Protection (EWP), ideal for outdoor installation where the unit is exposed to precipitation or condensation. EWP products are designed to meet IP66 standards and may feature foam rubber gaskets, sealed connections, gel-filled butt connectors, as well as potted circuit boards with internally sealed, field-adjustable trim pots and DIP switches for easy on-site programming. For more information on Enhanced Weather Protection (EWP), click here.

Applications

  • Emergency pool phones
  • Gas stations
  • EV charging stations
  • Water parks
  • Amusement parks
  • Parking ramps/lots
  • Entryways
  • Campus emergency stations
  • Roadside emergency stations
  • Stadiums
  • Convention centers

Features

  • Fits seamlessly within Viking VE-9×12 Outdoor Enclosures
  • Automatic polling and programming software included
  • 2 Amp relay contacts for door/gate or SL-2 strobe light control
  • SIP compliant
  • Outbound Proxy, Authentication ID, Peer to Peer, VLAN Tagging
  • PoE powered (class 1, <4 Watts)
  • Automatic Noise Canceling (ANC) for clear audio, even in noisy environments
  • Meets ADA requirements for Emergency Phones:
    • Automatically lights the “Call Connected” LED
    • Transmits a unique location I.D. code or voice announcement
    • Grade 2 Braille label for the visually impaired
  • Non-volatile digital voice announcer with 28 seconds of voice memory
  • Handsfree operation
  • Dials up to 5 emergency numbers
  • Cycles through backup phone numbers on busy or no-answer
  • Hangs up on busy signal, time-out or touch tone command
  • Extended temperature range of -40°F to 140°F
  • VoIP eliminates the need for “Push to Talk” mode
  • Network downloadable firmware
  • Diagnostics for testing microphone, speaker, and relay
  • Includes Enhanced Weather Protection (EWP), EWP products are designed to meet IP66 Ingress Protection Rating
  • Optional VE-SPG Hinge Spring
  • Optional PB-100 Polling System
  • Optional BLK-4-EWP Strobe Light Kit
  • Optional LC-6 Six Port Concentrator
  • Optional red “Emergency” label (part 261529) for VE-9×12 Enclosure

Certifications

  • EWP
  • CE
  • Canada ICES
  • FCC Part 15
  • ADA
  • SIP

Specifications

  • Power:  PoE class 1 (<4 Watts)
  • Maximum Sound Pressure:  95 dB SPL @ 1m
  • Dimensions: 11.225” x 7.08” x 2.0” (299 mm x 216 mm x 51 mm)
  • Operating Temperature:  -40°F to 140°F (-40° C to 60° C)
  • Humidity:  Up to 100%
  • Shipping Weight: 2.3 lbs (1.04 kg)
  • Material: Brushed marine grade 316 stainless steel
  • Mounting: Mounts to Viking model VE-9X12(R/Y/B)-0P
  • Audio Codecs:  G711u, G711a, G722
  • Network Compliance:  IEEE 802.3 af PoE, SIP 2.0 RFC3261, 100BASE-TX with auto cross over
  • Regulatory Compliance:  CE, FCC Part 15 and Canada ICES-003 Class A
  • Connections: (1) RJ45 10/100 Base-T, color-coded wires with gel-filled butt connectors

Compare With Similar Items

  • Dimensions: 9.375″ x 12.6″ x 7.45″ (238 mm x 320 mm x 189 mm)
  • Shipping Weight: 6.6 lbs (2.99 kg)
  • Material: Heavy-duty UV stable polycarbonate / ABS composite
  • Mounting: Mounting holes can be drilled where needed in the back of the enclosure
  • Conduit Openings: Conduit holes can be drilled where needed in the bottom of the enclosure
  • Flame Retardancy: Meets UL 94 V-0 rating
  • NEMA Rating: Designed to meet NEMA / EEMAC Type 4, 4X and 12 requirements
  • Dimensions: 9.375″ x 12.6″ x 7.45″ (238 mm x 320 mm x 189 mm)
  • Shipping Weight: 6.6 lbs (2.99 kg)
  • Material: Heavy-duty UV stable polycarbonate / ABS composite
  • Mounting: Mounting holes can be drilled where needed in the back of the enclosure
  • Conduit Openings: Conduit holes can be drilled where needed in the bottom of the enclosure
  • Flame Retardancy: Meets UL 94 V-0 rating
  • NEMA Rating: Designed to meet NEMA / EEMAC Type 4, 4X and 12 requirements
  • Dimensions: 9.375″ x 12.6″ x 7.45″ (238 mm x 320 mm x 189 mm)
  • Shipping Weight: 6.6 lbs (2.99 kg)
  • Material: Heavy-duty UV stable polycarbonate / ABS composite
  • Mounting: Mounting holes can be drilled where needed in the back of the enclosure
  • Conduit Openings: Conduit holes can be drilled where needed in the bottom of the enclosure
  • Flame Retardancy: Meets UL 94 V-0 rating
  • NEMA Rating: Designed to meet NEMA / EEMAC Type 4, 4X and 12 requirements

Questions?

We are here for you!

Contact Us
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.