Menu

Emergency Phone with Enhanced Weather Protection for Viking Outdoor Enclosures

Model: E-1600-912A-EWP

  • Fits seamlessly within Viking VE-9×12 Outdoor Enclosures
  • Optional cellular connectivity using compatible third-party cellular to POTS converters
  • Automatic Noise Canceling (ANC) feature for clear audio in noisy environments
  • Meets ADA requirements for Emergency Phones:
    • Automatically lights the “Call Connected” Buttons LED
    • Transmits a unique location I.D. code or voice announcement
    • Grade 2 Braille label for the visually impaired
  • Non-volatile digital voice announcer with 16 seconds of voice memory
  • Advanced call progress detection
  • Handsfree operation
  • Phone line powered
  • Non-volatile memory (no batteries required)
  • Marine grade 316 stainless steel prevents corrosion
  • Dials up to five emergency numbers
  • Cycles through backup phone numbers on busy or no-answer
  • Hangs up on CPC, silence, busy signal, dial tone, time-out or touch tone command
  • Programmable to auto-answer on incoming calls
  • Remotely programmable
  • Extended temperature range (-30°F to 170°F)
  • Central Station Monitoring capability (dials 2 numbers)
  • Includes Enhanced Weather Protection (EWP), EWP products are designed to meet IP66 Ingress Protection Rating
  • Optional VE-SPG Hinge Spring
  • Optional PB-100 Polling System
  • Optional BLK-4-EWP Strobe Light Kit
  • Optional LC-6 Six Port Concentrator
  • Optional red “Emergency” label (part 261529) for VE-9×12 Enclosure
View all features
Add to Pick List Added to Pick List
Software & Downloads

Product Manual

Questions?

We are here to help!

Viking Electronics

Product Details

The E-1600-912A-EWP ADA Compliant Emergency Phone is designed to fit in Viking VE-9×12 Outdoor Enclosures. They provide quick and reliable handsfree communication for any standard analog telephone line, analog phone system station port, or cellular to POTS converter. The E-1600-912A-EWP phone meets ADA requirements for emergency telephones, and can be programmed from any touch tone phone. The phone can dial up to 5 programmable emergency numbers, as well as 2 central station numbers.

The E-1600-912A-EWP phone can be programmed to automatically deliver a digital announcement to identify the location of the emergency call. Alternatively, a DTMF touch tone code may also be delivered. A “Call Connected” LED can be initiated manually or automatically. All programming parameters, including phone numbers and location numbers, are stored in non-volatile memory. This unit is phone line powered, requiring no batteries or external power and is compatible with common Central Station Monitoring equipment.

The E-1600-912A-EWP is equipped with Enhanced Weather Protection (EWP), ideal for outdoor installation where the unit is exposed to precipitation or condensation. EWP products are designed to meet IP66 standards and may feature foam rubber gaskets, sealed connections, gel-filled butt connectors, as well as potted circuit boards with internally sealed, field-adjustable trim pots and DIP switches for easy on-site programming. For more information on Enhanced Weather Protection (EWP), click here.

Viking Electronics

Applications

  • Emergency pool phones
  • Gas stations
  • EV charging stations
  • Water parks
  • Amusement parks
  • Parking ramps/lots
  • Entryways
  • Campus emergency stations
  • Roadside emergency stations
  • Stadiums
  • Convention centers

Features

  • Fits seamlessly within Viking VE-9×12 Outdoor Enclosures
  • Optional cellular connectivity using compatible third-party cellular to POTS converters
  • Automatic Noise Canceling (ANC) feature for clear audio in noisy environments
  • Meets ADA requirements for Emergency Phones:
    • Automatically lights the “Call Connected” Buttons LED
    • Transmits a unique location I.D. code or voice announcement
    • Grade 2 Braille label for the visually impaired
  • Non-volatile digital voice announcer with 16 seconds of voice memory
  • Advanced call progress detection
  • Handsfree operation
  • Phone line powered
  • Non-volatile memory (no batteries required)
  • Marine grade 316 stainless steel prevents corrosion
  • Dials up to five emergency numbers
  • Cycles through backup phone numbers on busy or no-answer
  • Hangs up on CPC, silence, busy signal, dial tone, time-out or touch tone command
  • Programmable to auto-answer on incoming calls
  • Remotely programmable
  • Extended temperature range (-30°F to 170°F)
  • Central Station Monitoring capability (dials 2 numbers)
  • Includes Enhanced Weather Protection (EWP), EWP products are designed to meet IP66 Ingress Protection Rating
  • Optional VE-SPG Hinge Spring
  • Optional PB-100 Polling System
  • Optional BLK-4-EWP Strobe Light Kit
  • Optional LC-6 Six Port Concentrator
  • Optional red “Emergency” label (part 261529) for VE-9×12 Enclosure

Certifications

  • EWP
  • IP66
  • FCC Part 15
  • ADA

Specifications

Power Telephone line powered. Minimum 24V DC talk battery voltage, with a minimum loop current of 20mA loop. Loop current may be boosted on low current lines with a Viking model TBB-1B Talk Battery Booster.
Operating Temperature -30° F to 170° F (-34° C to 77° C)
Humidity Up to 100% non-condensing

Compare With Similar Items

  • Power: Telephone line powered. Minimum 24V DC talk battery voltage, with a minimum loop current of 20mA loop. Loop current may be boosted on low current lines with a Viking model TBB-1B Talk Battery Booster.
  • Operating Temperature: -30° F to 170° F (-34° C to 77° C)
  • Humidity: 5% to 95% non-condensing
  • Dimensions: 9.375″ x 12.6″ x 7.45″ (238 mm x 320 mm x 189 mm)
  • Shipping Weight: 6.6 lbs (2.99 kg)
  • Material: Heavy-duty UV stable polycarbonate / ABS composite
  • Mounting: Mounting holes can be drilled where needed in the back of the enclosure
  • Conduit Openings: Conduit holes can be drilled where needed in the bottom of the enclosure
  • Flame Retardancy: Meets UL 94 V-0 rating
  • NEMA Rating: Designed to meet NEMA / EEMAC Type 4, 4X and 12 requirements
  • Dimensions: 9.375″ x 12.6″ x 7.45″ (238 mm x 320 mm x 189 mm)
  • Shipping Weight: 6.6 lbs (2.99 kg)
  • Material: Heavy-duty UV stable polycarbonate / ABS composite
  • Mounting: Mounting holes can be drilled where needed in the back of the enclosure
  • Conduit Openings: Conduit holes can be drilled where needed in the bottom of the enclosure
  • Flame Retardancy: Meets UL 94 V-0 rating
  • NEMA Rating: Designed to meet NEMA / EEMAC Type 4, 4X and 12 requirements

Questions?

We are here for you!

Contact Us
Viking Electronics
Viking Electronics
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.